Pith. sign in

REVIEW 1 cited by

Millilensing induced systematic biases in parameterized tests of General Relativity

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2410.21738 v1 pith:SWXU2VUW submitted 2024-10-29 gr-qc astro-ph.HEhep-ph

Millilensing induced systematic biases in parameterized tests of General Relativity

classification gr-qc astro-ph.HEhep-ph
keywords modelgeneralrelativitysystematicunlensedwhenanalysisbiases
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Tests of general relativity (GR) can be systematically biased when our waveform models are inaccurate. We here study systematic biases in tests of general relativity induced by neglecting lensing effects for millilensed gravitational-wave signals, where the lens mass is typically in the $10^3M_\odot$--$10^5M_\odot$ range. In particular, we use a nested-sampling Bayesian parameter estimation and model selection analysis of a millilensed signal with an unlensed parameterized post-Einsteinian (ppE) recovery model. We find that the ppE model is significantly biased toward a detection of a deviation from general relativity at signal-to-noise ratios of 30 and higher, especially when the source is aligned with the lens mass (the lensing effect is pronounced) and when its total mass is low (the signal duration is long). We use a toy model and the linear signal and Laplace approximations to provide a semi-analytic explanation for the trends in the systematic errors found in the nested sampling analysis. Moreover, a Bayes factor analysis reveals that the (unlensed) ppE model is weakly favored over the (unlensed) GR model, and a fitting factor study shows there is a significant loss of signal-to-noise ratio when using the (unlensed) ppE model. This implies that although a parameter estimation study may incorrectly infer a deviation from general relativity, a residual signal-to-noise ratio test would reveal that the ppE model is not a good fit to the data. Thus, with current detectors, millilensing-induced systematic biases are unlikely to result in false positive detections of GR deviations.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Biases in Tests of General Relativity from Microlensed Gravitational-Wave Signals

    gr-qc 2026-07 conditional novelty 5.0

    Microlensing in the wave-optics regime can push standard LIGO-Virgo-KAGRA general-relativity tests to false ~4–4.5σ deviations, even for signals that are perfectly consistent with GR.