Pith. sign in

REVIEW 1 cited by

Multi-View and Multi-Scale Alignment for Contrastive Language-Image Pre-training in Mammography

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2409.18119 v2 pith:CVUVBG4V submitted 2024-09-26 cs.CV cs.AIcs.LG

Multi-View and Multi-Scale Alignment for Contrastive Language-Image Pre-training in Mammography

classification cs.CV cs.AIcs.LG
keywords datamammographyalignmentclipmedicalmulti-viewavailablecontrastive
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Contrastive Language-Image Pre-training (CLIP) demonstrates strong potential in medical image analysis but requires substantial data and computational resources. Due to these restrictions, existing CLIP applications in medical imaging focus mainly on modalities like chest X-rays that have abundant image-report data available, leaving many other important modalities underexplored. Here, we propose one of the first adaptations of the full CLIP model to mammography, which presents significant challenges due to labeled data scarcity, high-resolution images with small regions of interest, and class-wise imbalance. We first develop a specialized supervision framework for mammography that leverages its multi-view nature. Furthermore, we design a symmetric local alignment module to better focus on detailed features in high-resolution images. Lastly, we incorporate a parameter-efficient fine-tuning approach for large language models pre-trained with medical knowledge to address data limitations. Our multi-view and multi-scale alignment (MaMA) method outperforms state-of-the-art baselines for three different tasks on two large real-world mammography datasets, EMBED and RSNA-Mammo, with only 52% model size compared with the largest baseline. The code is available at https://github.com/XYPB/MaMA

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. Benchmarking the Robustness of Foundation Models for Mammography under Domain Shift

    cs.CV 2026-07 conditional novelty 6.0

    Mammography-specific VLMs lead mean OOD linear-probe performance across 15 datasets, but robustness depends on pretraining objective and is highly dataset-heterogeneous, not on mammography exposure alone.